Vendor:
Designed in accordance with the VITA 75 footprint, the M-Max® VI 1 DS is a fully sealed rugged computer system with passive cooling, providing reliable operation in tough environments including transportation, agriculture, mining and processing.
Its machine-worked aluminum chassis is especially designed for the most challenging environments.
The system’s GPSS module supports GPS/Glonass/Galileo/BeiDou/QZSS.
The VITA 75 compliant M-Max® VI 1 DS system is guaranteed to operate in −40 to +60°C.
The embedded power supply complies with MIL-STD-704F/461F specifications.
|
Technical specifications |
|
| CPU | Intel Core i7-8665U @ 2133 MHz |
| Cores / Threads | 4 / 8 |
| RAM | 16GB DDR4 |
| GPU | Intel UHD Graphics for 8th Generation Intel Processors |
| Data storage | 960 GB, Standard SATA, m.2 2242 socket, PCIe |
| Video | 2 HDMI /1x LVDS |
| Audio | HDA audio to analog audio converter |
| DIO | 8 programmable direction digital I/O |
| LAN | 2x Gigabit Ethernet ports 10/100/1000 Mbps |
| Serial ports | 4x multiprotocol RS-232/422/485 through SP336 |
| USB | 4x USB 2.0, 2x USB 3.0 |
| GNSS support | GPS / Glonass / Galileo / BeiDou / QZSS |
| Operating system | Windows 10 64-bit and Ubuntu Linux 64-bit |
| Connectors |
1x D38999/20FA98PN (Power); 1x D38999/20FC35PN (1x HDMI) 1x D38999/20FE35SN (1x USB 3.0, 1x USB 2.0, 2x RS-232, 1x RS-422, 2x Gigabit Ethernet, 1PPS) 2x SMA connectors (1x GNSS Antenna / 1x 10 MHz output) All connectors are IP67 |
| Power |
28V DC (12V - 36V DC, Isolated) power supply compliant with MIL-STD-704F, MIL-STD-461F |
| Power Consumption | 60 W |
| Indication | 1 x for ‘Power In’ (Green) |
| Enclosure | Aluminum enclosure, Passive cooling system (no fans) |
| Mechanical (W x H x L) |
284.48 x 57.8 x 188 mm (without connectors and endcaps) |
| Weight | About 2.5 Kg |
| MTBF | More than 60’000 hours |
|
Environmental and physical specifications |
|
|---|---|
| Operating / Storage Temperature |
-40 to +60 °C / -40 to +85 °C, Complies with MIL-STD-810G (High temp. method 501.5, Low temp. method 502.5, Procedure I, II) |
| Humidity | Operating: 5 to 95 % at +25 °C, non-condensing |
| Vibration |
Operating acceleration amplitude up to 2.5g (3–500 Hz) Complies with MIL-STD-810G (Method 514.6, Category 14, 20) |
| Shock |
Maximum peak shock acceleration up to 40g (11 ms) TPS 3 axis Complies with MIL-STD-810G (Method 516.6, Procedure V) |
| Dust/Moisture: | IP66 |